  1. Preparations
    • Checking for correct function of the environment, in particular function of the scanner.
    • Manual stop of BVQ Scanner and Alerting-service, Scheduler-services and also of all GUIs and reporting-clients
    • Backup of BVQ installation directory and BVQ DB (e.g. DB offline backup with DB2 CMD) 
    • Starting again the BVQ Scanner
  2. Update BVQ Install Package Repository: bvq-package-repository-installer-x64-V3.2.exe
    1. DB Schema update
    2. BVQ GUI update
    3. BVQ Reporting Engine update
    4. BVQ Report Module update
    5. BVQ SVC Scanner update (warning)*
    6. BVQ VMware Scanner update
    7. BVQ Scheduler update
    8. BVQ Alerting update
  3. Performing functional tests
  4. If necessary inform colleagues about the need to update locally installed BVQ GUI / report clients. 

 

...

PDF Version

Viewtracker

 

Hinweise

Note
titleBitte beachten

Ab Version 3.0 ist der Upgrade von DB2 auf Version 10.5 FP4 zwingend erforderlich.
Bitte laden Sie daher zuerst diese DB2 Version von der IBM Webseite und führen dann den Upgrade durch. Eine Anleitung dazu finden Sie in folgendem Dokument: DB2 Upgrade von Version 9.7 auf 10.5

Ab Version 2.9 wird eine neue Lizenzdatei empfohlen.
Sie können aber auch die alte Lizenzdatei weiterverwenden. In diesem Fall werden neue Features im Lizenz-Dialog als "Missing" angezeigt und sind damit deaktiviert. Ansonsten beeinträchtigt dies die Funktion von BVQ nicht weiter.

...