borderColor | #248D51 |
---|---|
titleColor | white |
borderWidth | 3 |
titleBGColor | #248D51 |
borderStyle | solid |
title | Brocade SAN Switch preparation |
...
Table of Contents | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Panel | ||
---|---|---|
| ||
Brocade SANOnly one scanner configuration per SAN is required. Switches in access gateway mode are not part of the fabric, and hence, have to be added to the configuration manually. FOS REST API function calls are permitted or denied based on user privilege configurations determined by the role-based access control (RBAC) functionality in Fabric OS. Brocade REST API is supported on SAN switches running Fabric OS 8.2.1 and later but we recommend to use FOS 9 and higher. All switches running earlier versions cannot be monitored by BVQ! ( |
...
see Supported Brocade systems).
For switches running FOS 9, the user needs at least the permissions of the default role basicswitchadmin for all virtual Switches and the chassis. It is recommended to have the same user credentials and access configuration (https / http and SSL certificate) on all Switches belonging to the same SAN. Depending on the specific FOS level, the following user has to be added on each and every switch you want to scan: |
...
Add BVQ user via FOS CLI (switches with VF)
|
...
Add BVQ user via FOS CLI (switches without VF)
Increase Rest sessions It is also an essential requirement to increase the number of allowed REST sessions to 10 on each switch in the fabric. This adjustment is a necessary step to ensure efficient operation. |
...
...
Increase the number of allowed Rest sessions to 10
BVQ scanner configurations need the following input:
|
...
...
Note: If switches or virtual fabrics are added to or removed from the SAN, the scanner configuration needs to be adjusted manually. Edit the scanner configuration and select "Discover switches" to rediscover the SAN. |
Panel |
---|
...
borderColor | #248D51 |
---|---|
titleColor | white |
borderWidth | 3 |
titleBGColor | #248D51 |
borderStyle | solid |
title | Cisco SAN preparation |
BVQ 2022.H2.1 and higher
...
| ||
Cisco SANBVQ collects topology and performance data from Cisco MDS switches using the Cisco MDS NX-API. This feature needs to be enabled on all Cisco MDS switches that should be monitored by BVQ. |
...
...
Enable nxapi
Cisco SAN Switch User The following user has to be added on each and every switch you want to scan: |
...
Add BVQ User via CLI
|
...
copy and paste following commands
|