direction | horizontal |
---|
...
title | BVQ Editions |
---|
BVQ is the base product with all its functionalities and the infrastructure layers Compute & HCI, Network and Storage.
The Base product offers editions that describe the range of functions.
Select the platforms you need to fill in the infrastructure layer.
The smallest possible installation only uses one platform.
Infrastructure end-to-end monitoring functions are available from two platforms in different layers.
BVQ Entry edition
Cost-effective entry for customers who want to professionally monitor their systems with tailored dashboards and historical time frames. BVQ Systems health map offers automated IT health status to identify critical situations. The traffic light visualization alerts and help with analysis steps. Reports can be scheduled.
This edition is pre-configured and can be easily installed and adjusted to a small extent on basic requirements. An essential strength of the Enterprise Edition: It can be connected to Incident Management Systems, Reporting Tools, CMDBS and Dashboard Solutions of the Customer and serves this as a central data and message source.
The Entry Edition additionally enables the integration of the customer environment to the SVA Operational Services, which ensure seamless and uninterrupted monitoring of the customer environment, as well as a quick troubleshooting on all detected incidents.
Monitoring and Reporting:
HTML Monitoring and Reporting with end-to-end coverage when more than one platform is installed.
Use the dashboards and reports contained in the scope of the edition.
Custom dashboards can be created
Reports can be scheduled
Alerting and Systems health map
More that 300 system alerts are ready for use. The results of these system alerts can be displayed in great detail in the BVQ System Health map.
System health map offers automated guided ration to analyze the reason for the alerts.
SVA operational service
...
These BVQ components are part of the Entry Edition
...
Achieve more with an upgrade to a higher BVQ Edition.
- You have the following benefits If you decide for an BVQ Enterprise Edition.
- solve performance issues quickly and onsite
- no need to send data offsite for analysis services
- use unrestricted time frames for monitoring and reporting
- Customize Dashboards, Reports and Alerts to optimally adapt them to your needs.
- use System Health map without any restriction for example to plan your daily administrative tasks
- BVQ Alerting with alert notifications
- BVQ Connect REST interface to connect systems to your ITSM
BVQ Enterprise edition
The BVQ version for customers of all sizes who want to use the full range of BVQ functions and complete customization options. In addition to monitoring, alerting and reporting; the Enterprise Edition is ready for in-depth analysis of issues in the areas of load, performance and capacity growth, performance and cost optimization. Thanks to the integrated Connect Package, it serves as the central data and message source for externally connected ITSM and Business Intelligence systems.
...
Applications available for Enterprise Edition
- BVQ Server
- BVQ Monitoring web interface with prepared monitoring and analysis dashboards and the ability to create customized dashboards.
- BVQ Reporting with prepared standard reports, custom report creation and report scheduling & notification
- BVQ Systems Health Map with SHM analytics and customer categories.
- BVQ Alerting with prepared system alert templates & system checks, advanced custom alert rules, alert result display, alert notification
- BVQ Connect REST interface
Tabular list of BVQ editions
...
Compute: 1TiB RAM
Network: 100 Ports
Storage: 250 TiB
...
Additional license fees depending on edition
...
31 days
...
unlimited
...
180 days
...
unlimited
...
3 days
...
unlimited
...
Analysis
...
Monitoring
...
Custom monitoring dashboards
...
Reporting
...
Standard Reports
...
Custom reports
...
Scheduling & Report Notification
...
Datasources REST
...
Standard Alerts for Systems Health map
...
Custom alerts
...
Alert notifications
...
BVQ Systems Health Map
...
SHM Custom categories
...
title | License information |
---|
BVQ licensing overview
...
BVQ° licensing overview
BVQ° is licensed as a combination of
...
BVQ° editions and capacities entitlements:
Editions & Packages | Free edition Entry edition Enterprise edition |
---|---|
Capacity entitlements | Compute layer ( |
...
GiB Memory*) Network layer (Ports) Storage layer (TiB) |
For very large installations, other licensing methods can be used that are mutually beneficial.
...
* Memory based Compute layer licensing available since BVQ° release 2023.H1 (see below)
BVQ° editions & packages
...
BVQ° functionality is tailored to the typical needs of different infrastructure sizes and customer demands:
...
BVQ° Enterprise edition | Full |
---|
...
functionality: Monitoring, reporting, alerting & analysis |
...
BVQ° Connect package |
...
BVQ° Entry edition | Major |
---|
...
functionality: Monitoring, reporting, alerting |
...
BVQ° Free edition | Basic functionality for a limited environment size |
---|
https://bvq-software.de/en/bvq-license
BVQ° capacity entitlements
The size of a
...
BVQ° managed environment is measured with capacity entitlements. Each
...
BVQ° edition has a specific price for one of the three following entitlement types related to an IT-
...
infrastructure layer grouping the platforms and their systems supported by BVQ. Entitlements are marketed in packages, that contain a specific count of entitlements.
Layer | Licence Entitlement |
---|
...
Packet size |
---|
...
...
Memory (RAM) capacity GiB count | 128 GiB | |
Port count | 25 Ports |
...
...
Managed Storage capacity TiB count |
...
10 TiB |
Compute layer Memory entitlements
BVQ° license is validated against the total count of GiB of installed Memory (RAM) of all Compute layer systems monitored by BVQ. The count is independent from the online state or usage of this capacity.
All Compute layer systems must be completely licensed by Virtual machine entitlements or be completely licensed by Memory entitlements. Partial entitlement intermix is not supported.
Compute layer licensing based on memory is available since BVQ° release 2023.H1 and replaces the Compute layer Virtual machine entitlements (see below).
...
Compute layer Virtual machine entitlements
...
If you are still using this type of entitlements, BVQ° license is validated against the total count of all Virtual machines or Logical partitions (VMs) configured of all systems monitored by BVQ. The count is independent from the online state or function of the VMs. IBM PowerVM VIOS are excluded from the count.
In case a
...
BVQ° OS Agent is used on a System that is already monitored via PowerVM HMC or VMware vSphere
...
BVQ° Scanners, no additional VM entitlement count is needed.
...
All Compute layer systems must be completely licensed by Virtual machine entitlements or be completely licensed by Memory entitlements. Partial entitlement intermix is not supported.
Compute layer licensing based on Virtual machine entitlements is no longer available since BVQ° release 2023.H1. A migration path to the new Compute layer Memory entitlements (see above) is available. Please ask your SVA contact for details.
BVQ° Compute layer licensing tries to keep the virtualization layer transparent
In a cascaded compute virtualization layer environment, for example Kubernetes containers running inside a VMware vSphere hypervisor, the memory capacity is only counted once. Memory discovered in upper compute container nodes provisioned from underlying compute hypervisor systems which are monitored and completely licensed by BVQ° is not validated against the BVQ° license. Otherwise, memory discovered in upper compute container nodes provisioned from underlying compute hypervisor systems which are not monitored and completely licensed by BVQ° is completely validated against the BVQ° license.
With that, you can add your Kubernetes environment without additional charge, if the underlying compute hypervisor system memory is licensed already. This provides the advantage of a deeper a end-to-end monitoring expertise.
Network layer Port entitlements
...
BVQ° license is validated against the total count of all ports of all switches and directors monitored by BVQ, which are activated by a license of the device vendor. The count is independent from the online state or function of the ports.
...
Ports on Core Routing blades in Brocade director class switches only count if a QSFP is plugged into such ports.
Storage layer Capacity entitlements
For the
...
IBM storage systems the
...
BVQ° license is validated against the total count
...
of managed storage pool capacity
...
TiBs of all systems monitored by BVQ. The count is independent from the online state or usage of the capacity.
Managed storage pool capacity
...
is based on the amount of total capacity that is provided by the storage system pools that can be assigned to volumes, filesystems or metadata. This capacity is typical less than the gross raw disk capacity and less than the capacity after volume data reduction (compression, de-duplication, thin provisioning, ...).
...
For all other storage systems the BVQ° license is validated against:
Netapp ONTAP: Total count of all drive size TiBs
Dell Unity: Total count of all pool capacity TiBs
Dell PowerStore: Total count of system physical capacity TiBs
Pure FlashArray: Total count of system capacity TiBs
NetApp ONTAP Metrocluster
The capacity of Disk Enclosures shared between two NetApp ONTAP IP or FC Metro clustered Systems is only counted once.
BVQ° Storage layer licensing tries not to take care where data reduction takes place
In case
...
of volume data reduction: This does not affect the total managed capacity of the pools, so it does not affect the
...
BVQ° license.
In case
...
of pool data reduction:
...
BVQ° license is validated against the smaller physical allocatable capacity not the logical capacity.
In case
...
of drive level data reduction:
...
BVQ° license is validated against the smaller physical allocatable capacity not the logical capacity. This is currently only applicable for some systems. All other systems need to be licensed for the pool capacity as explained above.
...
BVQ° respects drive level data reduction for the following systems:
IBM Storwize family systems
IBM FlashSystems
In case
...
of thin provisioned MDisks
...
provisioned from BE Systems to the Storage virtualization layer (eg IBM Spectrum virtualize (SVC)), the sum of the physical capacity and the sum of the logical capacity is calculated and only the smallest of both results is counted (since
...
BVQ° release 2021.H2).
The support of thin provisioned MDisks in the virtualization layer. is required for that. IBM supports that feature for a growing number of backend storage subsystems from IBM and other vendors.
...
BVQ° Storage layer licensing tries to keep
...
the virtualization layer transparent
In the storage virtualization layer,
...
the managed storage pool capacity
...
of storage pools provisioned by backend storage subsystems monitored and completely licensed by
...
BVQ° is not
...
validated against the
...
BVQ° license. Otherwise, managed storage pool capacity
...
of storage pools provisioned by backend storage
...
subsystems not
...
monitored by
...
BVQ° is
...
completely validated against the
...
BVQ° license.
You can take the following advantages by including supported backend storage subsystems in your
...
BVQ° monitoring:
This may decrease the amount of licensed
...
BVQ° capacity, in case data reduction takes place inside the backed subsystems .
...
e, without additional charge if the backend subsystem capacity is completely provisioned to the virtualization layer.
...
BVQ° Storage layer licensing example calculation (based on TiB)
Backend subsystem | Virtualization layer | BVQ |
---|
...
BVQ° monitored? | Drive physical | Drive logical | Pool physical capacity | Pool logical capacity | Volume logical capacity | pool logical | Licensed | Reason why |
---|---|---|---|---|---|---|---|---|
100 | 100 | 100 | 100 | 100 | 100 | 100 | No data reduction at all | |
100 | 100 | 100 | 100 | 200 | 200 | 100 | Volume level data reduction in BE subsystem is respected by BVQ | |
100 | 100 | 100 | 200 | 200 | 200 | 100 | Pool level data reduction in BE subsystem is respected by BVQ | |
100 | 200 | 100 | 200 | 200 | 200 | 100 | Drive level data reduction in BE subsystem is respected by BVQ | |
N/A (50) | N/A (100) | 50 | 100 | 100 | 100 | 100 | Drive level data reduction in BE subsystem not listed to be respected by BVQ | |
N/A | N/A | N/A | N/A | N/A (100) | 100 | 100 | No information from BE subsystem: Virtualization layer pool logical capacity counts. | |
100 | 100 | 100 | 100 | 100 | 50 | 100 | Not all capacity of a BE subsystem managed by |
...
BVQ° is provisioned to the virtualization layer: Total managed BE System capacity counts. | ||||||||
N/A | N/A | N/A | N/A | N/A (200) | 100 | 100 | Not all capacity of the BE subsystem is provisioned to the virtualization layer: Virtualization layer capacity counts. | |
---|---|---|---|---|---|---|---|---|
N/A | N/A | 100 | N/A | 200 | 200 | 100 | Inline inquiry information from BE subsystem via thin provisioned MDisks: | |
N/A | N/A | 200 | N/A | 100 | 50 | 100 | Inline inquiry information from BE subsystem via thin provisioned MDisks, but |
Storage layer Enclosure entitlements
This way of licensing is withdrawn from market
...
since . Customers with an active
...
BVQ° license may still extend their systems with that type of license.
For eligible storage systems, the
...
BVQ° license is validated against the total count of all enclosures containing disk drives (controller an expansion enclosures). The count is independent from the online state of the enclosure.
The following storage systems are eligible for
...
BVQ° enclosure based licensing: IBM Storwize V5000, V7000, V7000F
All Storwize systems' capacity below SVC is not eligible for enclosure based licensing.
Standalone Storwize
...
systems not attached to SVC, must be completely licensed by enclosure or be completely licensed by capacity entitlements. Partial entitlement intermix is not supported.
A typical scenario is: A customer has some Backend systems below SVC and some other eligible Storwize systems not connected to the SVC so they are directly provisioning some hosts with storage capacity. Here the customer can license the direct attached systems by
...
BVQ° enclosure based licensing and the SVC Capacity by
...
BVQ° capacity based licensing.
...
...
General Terms
...
& Conditions
...