titlePlease note

Starting with version 3.0 the upgrade from DB2 to version 10.5 FP2 FP5 is mandatory.
Please download first this DB2 version from the IBM website and then perform the upgrade. For instructions, please see the following document: DB2 upgrade from version 9.7.4 or higher to 10.5.

 
From version 2.9 a new license file is recommended.
Continued use of the old license file is also possible. In this case, new features will appear as 'Missing' in the license dialog and are thus deactivated. Otherwise the function of BVQ is not affected. 

Highlights

...

SVC 7.4 toleration support

New functions

Issue ID

Module

Description

BVQ-8450CommonSVC 7.4 toleration support

Improvements

Cluster selection dialog: show SVC code level and modify default sorting

Issue ID

Module

Description

BVQ-8411

GUI

8326

GUI

Performance view: consolidate various axes

BVQ-8350

GUI

Docking: design of a clearer appointment in the Windows task bar

BVQ-8445

GUI

Context menu: performance view: arranging general order depending on SVC layer

BVQ-8511

GUI

DB connection profile: improve handling by File Chooser

BVQ-8520

GUI

Performance view: cache partition: point tooltip: update of IO group specification

Bug fixes

Critical

Issue ID

Module

Description

BVQ-8603

SVC Scanner

V7000-300 SAS ports lead to scan errors - quick fix: SAS ports and performance will not be scanned. Final fix in 3.3.3

BVQ-8493

SVC Scanner

Topology: exception with firmware version 7.1.0.2

BVQ-84598588

DB schema Schema migration

Issue ID

Module

Description

BVQ-8392

GUI

Treemap search: several selected objects from different levels lead to an exception

BVQ-8413

GUI

JDBC connection timeouts during slow connections

BVQ-8415

GUI

Migscript Failure at Mig-skript 3.3.0.20 for table PERF_SVC_NODE_PORT sometimes fails

This means that no node port stats are recognized anymore and the directory BVQ-scanner/iostat/instanceX/error is filled up.

BVQ-8460

DB schema migration

Some run-time errors during the execution of mig scripts in DB2CMD are ignored.

Important

Performance view: node CPU core metric tooltip doesn't show core ID19

BVQ-8481

Schema migration

Prereq check not sufficient for owner

Important

Issue ID

Module

Description

BVQ-8607

GUI

Context menu: VDisk group: exception during calling if no VDisks are included

BVQ-8566

GUI

DB/Cluster selection dialogue: DB connection error in user names with special characters

BVQ-8393

GUI

DB/Cluster selection dialogue: error message when adding new DB connections

BVQ-8409

GUI

Performance view: node port: NPE when calling the node port performance views of a V3700

BVQ-8416

GUI

Performance view: node to node: Y-axis of data rate does not respect  lower scaling limit 

BVQ-8431

GUI

Performance view: untitled favorites cause an exception / some performance favorites don`t have generated name / overwrite doesn`t work

BVQ-8441

GUI

Performance view: options: object list: default sorting not always related to primary column

BVQ-8442

GUI

Performance view: options: object list: remove of multiple objects in a sorted table is faulty

BVQ-8458

GUI

Performance view: drawing metric-sequence  not correct in node port BBCZ and MDisk

BVQ-8443

GUI

Favorites: performance view: favorites of some object types are grayed out unexpectedly

Issue ID

Module

Description

BVQ-84108402

GUI

Performance view: show VDisk & VDiskCopy cannot be opened with IO group

BVQ-8418

GUI

Performance view: Node2Node: inconsistent tab name und perf-view options window title

...

Docking: when all tabs are closed in the main window,  no tabs from the existing undock main windows can be pulled out into the main window anymore

BVQ-8403

GUI

Docking: X-button: when a tab is taken with D&D out from the main window , a undock main window without X button is produced

BVQ-8404

GUI

Docking: X-button: when a new tab is created via '+' button in the undock main windows. It reappears after changing the input focus

BVQ-8440

GUI

Performance view: options: object list: remove of a visible object causes the visibility of the uppermost

BVQ-8490

GUI

Favorites: rename favorite has no effect on the name in add favorite.

Known Problems

Issue ID

Module

Description

IBM PMR 91765,033,724SVC 6.2.0.3Severe impairment of the VDisk latency by the SVC CLI command 'lsmdiskextent'. Seen at a cluster with 8 nodes (8G4) under 6.1.0.4.
Starting with BVQ 2.4.3 this command is not used anymore. Instead command 'Isvdiskextent' is used. 
IBM PMR
unknown
SVC 6.4.0.3

Massive accumulation of reaching the SVC limit of 10 simultaneously competitive SSH sessions can trigger a warm restart of the node.
Fixed with 6.4.1.3

BVQ-6610BVQ VMwareMultiple mappings of a VM virtual disk (and/or of different snapshot versions of a single VM) to a VM virtual machine are not supported yet.      
This happens for example with flash copy managers like TSM4VE. 
BVQ-6623BVQ VMwareScan and representation snapshots and thier capacities are not yet supported by BVQ. The 'Used Capacity' of a VM Virtual Disk corresponds currently to the 'Used Capacity' of the original VMDK file 
IBM PMR ?SVC performance stats

Starting with version 6.1.0.1  SLAV, PLAV and DLAV refer to the consolidated backend IO sizes of up to 256k. But not the IO-counter for CTRM and CTP, which means that their quotient may be too low by a factor of 8. Therefore, the VDisk below   cache metrics SLAV and PLAV cannot be used directly to assess the backend latencies. Also their transaction size is not the same of the backend (max 32k).

However, CTD was adapted to the consolidated IO sizes and provides continuously useful values.

IBM PMR ?SVC 7.3
performance stats
Legacy VDisk cache statistics corrupted
IBM PMR ?SVC 7.3
performance stats
Node CPU Core stats =0
IBM defect 197194

SVC 7.3 Performance Statsperformance stats

CPT, OPT, APT much too high
BVQ-8602GUI Nodes of models V7000-100, V7000-300, V3700 are not properly differentiated because of the same node type 300 - fix expected in BVQ V3.4
BVQ-8589SVC ScannerIn V7000-300 systems FC and SAS ports have the same WWPN. Primary key is not properly implemented. Therefore SAS ports were completely removed from BVQ 3.3.2. Fix expected in BVQ V3.3.3

DB schema changes

Version
Tables
Description
3.3.0.2019PERF_SVC_NODE_PORTImproved order of the RENAME TABLE in the script for BVQ-8459Migsript adapted also for V5000 ports

Requirements and restrictions

...

Requirements of the HW/SW environment

Please see supported environments since BVQ 3.0

Minimum BVQ version required for an update

V2.7

DB2 version

DB2 Express Advanced Workgroup Server Edition V10.5 FP4FP5
Filename: v10.5fp5_ntx64_server_t.exe

Java Runtime minimum version1.7.0.71 (Java 1.8 not supported)

More information

Please see release notes für BVQ V3.3.1 

Notes

  • When configuring a topology scanner interval >30 min an adaptation in a GUI configuration file is necessary, concerning the scanner status checks. In this case please contact BVQ support.  
  • The Excel format generated by the BVQ Reporting is compatible with the Excel version of 2003 and higher.  
    This is the format 'XML spreadsheet 2003' (please see this Microsoft article for more information).
    The standard file extension for this format is '.xml'. If it is despite  saved with '.xls', a warning message appears when it is openend with Excel.
  • License changes only take effect after about 2 hours or after restarting the scanner and scheduler.
  • Currently not supported VMware functions:
    • Partitioned VM SCSI volumes, whose partitions are assigned to multiple VM datastores.
    • VM SCSI volumes whose UUIDs are not unique.

...

  1. Preparations
    • Checking for correct function of the environment, in particular function of the scanner.
    • Manual stop of BVQ Scanner and Alerting-service, Scheduler-services and also of all GUIs and reporting-clients
    • Backup of BVQ installation directory and BVQ DB (e.g. DB offline backup with DB2 CMD) 
    • Starting again the BVQ Scanner
  2. Update BVQ Install Package Repository: bvq-package-repository-installer-x64-V3.3.2.exe
    1. DB Schema update
    2. BVQ GUI update
    3. BVQ Reporting Engine update
    4. BVQ Report Module update
    5. BVQ SVC Scanner update (warning)*
    6. BVQ VMware Scanner update
    7. BVQ Scheduler update
    8. BVQ Alerting update
  3. Performing functional tests
  4. If necessary inform colleagues about the need to update locally installed BVQ GUI / report clients. 

 

PDF Version

...

 

Hinweise

Note
titleBitte beachten

Ab Version 3.0 ist der Upgrade von DB2 auf Version 10.5 FP4 zwingend erforderlich.
Bitte laden Sie daher zuerst diese DB2 Version von der IBM Webseite und führen dann den Upgrade durch. Eine Anleitung dazu finden Sie in folgendem Dokument: DB2 Upgrade von Version 9.7 auf 10.5

Ab Version 2.9 wird eine neue Lizenzdatei empfohlen.
Sie können aber auch die alte Lizenzdatei weiterverwenden. In diesem Fall werden neue Features im Lizenz-Dialog als "Missing" angezeigt und sind damit deaktiviert. Ansonsten beeinträchtigt dies die Funktion von BVQ nicht weiter.

Highlights

SVC 7.4 Toleration Support

Neue Funktionen

Issue ID

Modul

Beschreibung

BVQ-8450CommonSVC 7.4 Toleration Support

Verbesserungen

Issue ID

Modul

Beschreibung

BVQ-8326

GUI

Performance-Ansicht: Diverse Achsen konsolidieren

BVQ-8350

GUI

Docking: Benennung in der Windows Taskleiste klarer gestalten

BVQ-8445

GUI

Kontextmenü: Performance-Ansicht: Generelle Reihenfolge nach SVC Layers orientieren

BVQ-8511

GUI

DB Connection Profile: Handling durch File Chooser verbessern

BVQ-8520

GUI

Performance-Ansicht: Cache Partition: Punkt-Tooltip: Angabe der IO group ergänzen

Fehlerkorrekturen

Kritische

Issue ID

Modul

Beschreibung

BVQ-8603

SVC Scanner

V7000-300 SAS Ports führen zu Scan-Fehlern - QuickFix: SAS Ports und Performance wird nicht weiter gescannt. Final Fix in 3.3.3

BVQ-8493

SVC Scanner

Topology: Exception mit Firmware Version 7.1.0.2

BVQ-8588

Schema Migration

Fehlschlag bei Mig-Skript 3.3.0.19

BVQ-8481

Schema Migration

Prereq Check für Owner nicht ausreichend

Wichtige

Issue ID

Modul

Beschreibung

BVQ-8607

GUI

Kontextmenü: VDisk group: Exception beim Aufruf wenn keine VDisks enthalten sind

BVQ-8566

GUI

DB/Cluster Auswahldialog: DB Verbindungs-Fehler bei Benutzernamen mit Sonderzeichen

BVQ-8393

GUI

DB/Cluster Auswahldialog: Beim Hinzufügen neuer DB Connections kommt es zu einer Fehlermeldung

BVQ-8409

GUI

Performance-Ansicht: Node Port: NPE beim Aufruf der Node Port Performance Views einer V3700

BVQ-8416

GUI

Performance-Ansicht: Node to Node: Y-Achse von Data rate beachtet Untergrenze der Skalierung nicht

BVQ-8431

GUI

Performance-Ansicht: Favoriten ohne Name führen zur Exception / Manche PerformanceFavoriten haben keinen generierten Namen / Overwrite funktioniert nicht

BVQ-8441

GUI

Performance-Ansicht: Options: Objektliste: Default-Sortierung nicht immer nach Primäspalte

BVQ-8442

GUI

Performance-Ansicht: Options: Objektliste: Remove von mehreren Objekten in sortierter Tabelle fehlerhaft

BVQ-8458

GUI

Performance-Ansicht: Metrik-Reihenfolge beim Zeichnen nicht korrekt bei Node Port BBCZ und auch MDisk

BVQ-8443

GUI

Favoriten: Performance-Ansicht: Favoriten für einige Objekttypen werden unerwartet ausgegraut

Empfohlene

Issue ID

Modul

Beschreibung

BVQ-8402

GUI

Docking: Sobald im Main Window keinen Tab mehr offen ist, lässt sich kein Tab aus bestehenden Undock-Main-Windows heraus in das Main Window ziehen

BVQ-8403

GUI

Docking: X-Button: Zieht man einen Tab per D&D aus dem Main Window heraus, so entsteht ein Undock-Main-Window ohne X-Button

BVQ-8404

GUI

Docking: X-Button: Sobald im Undock-Main-Windows ein neuer Tab per +-Button erzeugt wird. Nach dem Wechseln des Input-Focus erscheint dieser wieder

BVQ-8440

GUI

Performance-Ansicht: Options: Objektliste: Remove eines visible Objektes führt zur Visibility des Obersten

BVQ-8490

GUI

Favoriten: Rename Favorite wirkt sich nicht auf den Namen in Add Favorite aus.

Bekannte Probleme

...

Issue ID

...

Modul

...

Beschreibung

...

Massiv gehäuftes Erreichen des SVC Limits von 10 gleichzeitig konkurrierenden SSH Sessions, kann einen Warmstart der Knoten auslösen.
Fixed seit 6.4.1.3

...

  1. .

...

CTD hingegen wurde auf die konsolidierten IO sizes angepasst und liefert weiterhin brauchbare Werte.

...

SVC 7.3 Performance Stats

...

DB Schema Änderungen

Version
Tabellen
Beschreibung
3.3.0.19PERF_SVC_NODE_PORTMigsript auch für V5000 Ports angepasst

Voraussetzungen und Einschränkungen

...

Voraussetzungen der HW/SW Umgebung

...

Siehe Unterstützte Umgebungen ab BVQ 3.0

...

Für eine Aktualisierung erforderliche BVQ Mindest-Version

...

V2.7

...

DB2 Version

...

DB2 Express V10.5 FP5

...

Weitere Hinweise

...

  1.  

...


  • Bei Konfiguration eines Topologie Scanner Intervalls >30min ist eine Anpassung in einer GUI Konfigurationsdatei, bezüglich der Scanner Status Checks, notwendig. Bitte in diesem Fall beim BVQ Support zurückfragen.
  • Das vom BVQ Reporting erzeugte Excel-Format ist kompatibel mit Excel ab Version 2003.
    Es handelt sich um das Format "XML Kalkulationstabelle 2003" (siehe Microsoft Artikel ).
    Die Standard Dateiendung für dieses Format ist: ".xml". Wird es trotzdem mit ".xls" abgespeichert, kommt es zu einer Warnmeldung beim Öffnen mit Excel.
  • Lizenzänderungen werden erst nach ca. 2h oder nach Neustart im Scanner und Scheduler wirksam.
  • Derzeit nicht unterstützte VMware Funktionen:
    • Partitionierte VM SCSI Volumes, deren Partitionen mehreren VM Datastores zugeordnet sind
    • VM SCSI Volumes deren UUIDs nicht eindeutig sind.

Kurzbeschreibung: Aktualisierungsschritte

Warning
titleHinweis zum Upgrade
  1. (warning)* beim Upgrade des BVQ Scanners von Version 2.7 auf 2.8 oder höher ist zu beachten, dass es neben dem SVC Scanner nun auch einen VMware Scanner geben kann. Deshalb wird er in ein neues Standard-Verzeichnis bvq-svc-scanner (vorher bvq-scanner) installiert. Um die vorhandene Scanner-Konfiguration wieder zu verwenden, sollte vor Durchführung des Aktualisierungsschritts 3. wie folgt vorgegangen werden:
    1. BVQ Scanner Services manuell stoppen
    2. Verzeichnis bvq-scanner umbenennen in bvq-svc-scanner
    3. Mit Aktualisierungsschritts 3. fortfahren.
  2. Um ggf. neue Funktionen nutzen zu können ist eine neue Lizenzdatei notwendig.
    Nach dem einspielen der neuen Lizenz ist ein GUI Neustart erforderlich.
  3. Die GUI wird mit neuen Predefined favorites ausgeliefert. Nur Favoriten unter User favorites bleiben erhalten.

Wir empfehlen die unten angegebene Reihenfolge der Aktualisierungsschritte einzuhalten.

 

...

  • Prüfung auf korrekte Funktion der Umgebung, insbesondere des Scanners.
  • BVQ Scanner-, Alerting-Service, Scheduler-Services und alle GUIs, Reporting-Clients manuell stoppen
  • BVQ Installation-Verzeichnis und BVQ DB sichern (z.B. DB Offline Backup mit DB2 CMD)
  • BVQ Scanner wieder Starten

...

 

...

...

PDF Version