- Preparations
- Check for correct function of the environment, especially the scanner.
- Stop BVQ scanner, alerting service, scheduler services, reporting-clients and all GUIs manually
- Backup BVQ installation directory and BVQ DB (e.g. DB offline backup with DB2 control center)
- Restart BVQ scanner
- Update DB schema:
bvq-schema-migration-3_0-installer.exe
- Update BVQ SVC scanner:
bvq-svc-scanner-3_0-installer.exe*
- Update BVQ VMware scanner:
bvq-vmware-scanner-3_0-installer.exe
- Update BVQ alerting:
bvq-alerting-
3_0
-installer.exe - Update BVQ scheduler:
bvq-scheduler-
3_0
-installer.exe - Update BVQ GUI:
bvq-gui-
3_0
-installer(-x64).exe - Update BVQ reporting engine:
bvq-reporting-birt-
3_0
-installer(-x64).exe - Update BVQ report module:
- Standard reports
bvq-standard-reports-
3_0
-installer.exe - Customized reports
custom-reports-[kundenname]-
3_0
-installer.exe
- Standard reports
- Perform functional tests
- If necessary, inform all colleagues about to the needed update of locally installed BVQ GUIs / report client
...