Release notes for BVQ V3.3
Notes
Please note
Starting with version 3.0 the upgrade from DB2 to version 10.5 FP2 is mandatory.
Please download first this DB2 version from the IBM website and then perform the upgrade. For instructions, please see the following document: DB2 upgrade from version 9.7.4 or higher to 10.5.
From version 2.9 a new license file is recommended.
Continued use of the old license file is also possible. In this case, new features will appear as 'Missing' in the license dialog and are thus deactivated. Otherwise the function of BVQ is not affected.
Highlights
Full support of SVC / Storwize version 7.3 including the new cache statistics
Displays now the node port performance statistics of types: FC, IPREP, iSCSI, SAS and PCIe
Multi screen support. Tabs can now be distributed in different windows on the desktop
New start screen allows selection of multiple BVQ installations on one host
Object type 'Disc type' now has an optional name and comment
Highlights details
SVC 7.3 cache metrics
Now the performance view additionally shows the new SVC 7.3 cache statistics. Only this allows a full analysis of the system's performance.
Particularly important advantages of the new 7.3 metrics are:
Real IO sizes: all IOs are counted in real transaction sizes and not, as before, limited by 32KiB cache tracks.
Upper / lower cache: they are displayed separated in upper cache and lower cache. All remaining 7.2 cache metrics are exclusively related to the upper cache.
VDisk copy metrics: now statistics are available at the level of VDisk copy. Thus, the load which is caused by a VDisk competing with others of the pool (MDisk group) can be determined exactly.
Previously this was not possible especially in cases when VDisk mirroring, space efficiency, compression or flash copy were used. Please note: the object type VDisk inherently contains only the upper cache metrics.
The matching lower cache metrics can be found in the correlating VDisk copy of a VDisk.End to end: the active chains in 7.3 can be represented as follows:
Reads
VDisk SCSI layer
→ VDisk upper cache
→ VDisk copy lower cache
→ MDisk queue outbound
→ Node port
Writes
VDisk SCSI layer
→ VDisk upper cache partiton
→ VDisk copy lower cache partition
→ MDisk queue outbound
→ Node port
The new 7.3 metrics can be selected in a third tab in the options dialogue of the performance view. Here, for example, the metrics for object type 'Node':
UNKNOWN ATTACHMENT
It can be recognized that they are now differentiated in upper and lower cache .
Port statistics for SAS, PCIe, FCoE, iSCSI, IPREP
Now BVQ additionally displays the node ports of not-FC types like SAS, PCIe, FCoE, iSCSI and IP replication in the treemap and in the performance view.
This completes the analysis options in the port area.
Here is a look on the node ports of a first generation V7000 :
UNKNOWN ATTACHMENT
Here the appropriate options-dialogue of the performance view, which allows the access to appropriate metrics:
UNKNOWN ATTACHMENT
Some port types like FC & FCoE, SAS and IP replication have specific metrics which are visible at the bottom in the metric selection.
Multi window docking
Tabs can now be converted into window areas. These areas can be extracted from the main window and be placed on the desktop or they can also be ordered within a window next to or above each other .
Thus, several performance views can be made visible simultaneously within one presentation. The distribution across multiple screens is also possible.
Here, for example, two treemaps next to each other with transferred selection :
UNKNOWN ATTACHMENT
Or multiple performance views of different types with identical time axis within one analysis.
UNKNOWN ATTACHMENT
DB connection profile
BVQ DB connection profiles include the access data to BVQ databases. BVQ client tools (currently GUI and reporting) use these whe establishing a connection and enable their management. The profiles are stored in '.bdp' files centrally within the installation directory and can be exchanged throughout the company. All locally installed client tools are using the same .bdp files.
A BVQ GUI or BVQ Reporting GUI can thus be easily switched on all configured BVQ databases.
The following screenshot shows the GUI's selection dialogue:
UNKNOWN ATTACHMENT
Encrypted passwords are stored in the .bdp files.
Please note: license-fees have to be paid for each additional BVQ DB.
Disk type name and comment
The BVQ object type Disk type now has got an optional name and a comment field. With this subtle differences between two similar disc types can be expressed better (for example: '3.5' vs '2.5', or SAS vs SATA vs FC or even different transmission speeds).
The name is optional. If not specified, or an existing name is cleared, BVQ derives automatically a new one based on the configured attributes .
If the name is entered , for example, in BVQ CLI scripts it can later be used for the allocation of disk arrays. As a result, scripts can be created containing a complete image of a disk subsystem. The previously necessary query of the BVQ ID after creating the disc types is no longer needed. So this script can also be created offline ( for example from tables).
New functions
Issue ID | Module | Description |
|---|---|---|
BVQ-7101 | Common | SVC 7.3: new cache architecture statistics integration |
BVQ-7183 | Common | Integration of SVC asset informationen into SVC nodes from lsnodehw (RAM, #CPU, #Cores) |
BVQ-7811 | Common | Object type: disk type: several improvements |
BVQ-7870 | Common | SVC 7.3: full support |
BVQ-7952 | Common | Node ports: integrate FC, IPREP, iSCSI, SAS, PCIe + show performance |
BVQ-8059 | Common | Node ports: FC: using expanded possibilities of Isportfc |
BVQ-7903 | DB | Tables for new perf stats from SVC 7.3 code |
BVQ-7683 | VMware scanner | Allow removing of a VM vCenter from the BVQ DB by using modified TopoFile |
BVQ-3682 | GUI | Multi window GUI (Jyloo Docking Framework) |
BVQ-8134 |