Release notes for BVQ V3.3

Release notes for BVQ V3.3

Notes

Please note

Starting with version 3.0 the upgrade from DB2 to version 10.5 FP2 is mandatory.
Please download first this DB2 version from the IBM website and then perform the upgrade. For instructions, please see the following document: DB2 upgrade from version 9.7.4 or higher to 10.5.

 

From version 2.9 a new license file is recommended.

Continued use of the old license file is also possible. In this case, new features will appear as 'Missing' in the license dialog and are thus deactivated. Otherwise the function of BVQ is not affected.

Highlights

  • Full support of SVC / Storwize version 7.3 including the new cache statistics

  • Displays now the node port performance statistics of types: FC, IPREP, iSCSI, SAS and PCIe

  • Multi screen support. Tabs can now be distributed in different windows on the desktop

  • New start screen allows selection of multiple BVQ installations on one host

  • Object type 'Disc type' now has an optional name and comment

Highlights details

SVC 7.3 cache metrics

Now the performance view additionally shows the new SVC 7.3 cache statistics. Only this allows a full analysis of the system's performance.
Particularly important advantages of the new 7.3 metrics are:

  • Real IO sizes: all IOs are counted in real transaction sizes and not, as before, limited by 32KiB cache tracks.

  • Upper / lower cache: they are displayed separated in upper cache and lower cache. All remaining 7.2 cache metrics are exclusively related to the upper cache.   

  • VDisk copy metrics: now statistics are available at the level of VDisk copy. Thus, the load which is caused by a VDisk competing with others of the pool (MDisk group) can be determined exactly.
    Previously this was not possible especially in cases when VDisk mirroring, space efficiency, compression or flash copy were used. Please note: the object type VDisk  inherently contains only the upper cache metrics.
    The matching lower cache metrics can be found in the correlating VDisk copy of a VDisk.

  • End to end: the active chains in 7.3 can be represented as follows:

    Reads

    VDisk SCSI layer

    → VDisk upper cache

    → VDisk copy lower cache

    → MDisk queue outbound

    → Node port

    Writes

    VDisk SCSI layer

    → VDisk upper cache partiton

    → VDisk copy lower cache partition

    → MDisk queue outbound

    → Node port

The new 7.3 metrics can be selected in a third tab in the options dialogue of the performance view. Here, for example, the metrics for object type 'Node':

UNKNOWN ATTACHMENT

It can be recognized that they are now differentiated in upper and lower cache .

Port statistics for SAS, PCIe, FCoE, iSCSI, IPREP

Now BVQ additionally displays the node ports of not-FC types like SAS, PCIe, FCoE, iSCSI and IP replication in the treemap and in the performance view.  

This completes the analysis options in the port area.

Here is a look on the node ports of a first generation V7000 :

UNKNOWN ATTACHMENT

Here the appropriate options-dialogue of the performance view, which allows the access to appropriate metrics:

UNKNOWN ATTACHMENT

Some port types like FC & FCoE, SAS and IP replication have specific metrics which are visible at the bottom in the metric selection.

Multi window docking

Tabs can now be converted into window areas. These areas can be extracted from the main window and be placed on the desktop or they can also be ordered  within a window next to or above each other .

Thus,  several performance views can be made visible simultaneously within one presentation. The distribution across multiple screens is also possible.

Here, for example, two treemaps next to each other with transferred selection :

UNKNOWN ATTACHMENT

Or multiple performance views of different types with identical time axis within one analysis.

UNKNOWN ATTACHMENT

DB connection profile

BVQ DB connection profiles include the access data to BVQ databases. BVQ client tools (currently GUI and reporting) use these whe establishing a connection and enable their management. The profiles are stored in '.bdp' files centrally within the installation directory and can be exchanged throughout the company. All locally installed client tools are using the same .bdp files.

A BVQ GUI or BVQ Reporting GUI can thus be easily switched on all configured BVQ databases.

The following screenshot shows the GUI's selection dialogue:

UNKNOWN ATTACHMENT

Encrypted passwords are stored in the .bdp files.

Please note: license-fees have to be paid for each additional BVQ DB.  

Disk type name and comment

The BVQ object type Disk type now has got an optional name and a comment field. With this   subtle differences between two similar disc types can be expressed better (for example: '3.5' vs '2.5', or SAS vs SATA  vs FC or even different transmission speeds).

The name is optional. If not specified, or an existing name is cleared, BVQ derives automatically a new one based on the configured attributes .

If the name is entered  , for example, in BVQ CLI scripts it can later be used for the allocation of disk arrays. As a result, scripts can be created  containing a complete image of a disk subsystem. The previously necessary query of the BVQ ID after creating the disc types is no longer needed. So this script can also be created offline ( for example from tables).

New functions

Issue ID

Module

Description

BVQ-7101

Common

SVC 7.3: new cache architecture statistics integration

BVQ-7183

Common

Integration of SVC asset informationen into SVC nodes from lsnodehw (RAM, #CPU, #Cores)

BVQ-7811

Common

Object type: disk type: several improvements

BVQ-7870

Common

SVC 7.3: full support

BVQ-7952

Common

Node ports: integrate FC, IPREP, iSCSI, SAS, PCIe + show performance

BVQ-8059

Common

Node ports: FC: using expanded possibilities of Isportfc

BVQ-7903

DB

Tables for new perf stats from SVC 7.3 code

BVQ-7683

VMware scanner

Allow removing of a VM  vCenter from the  BVQ DB by using modified TopoFile

BVQ-3682

GUI

Multi window GUI (Jyloo Docking Framework)

BVQ-8134