Changelog 2023.H1.3
Version 2023.H1.3
Features
Issue ID | Module | Description |
|---|---|---|
| BVQ-19158 | AIX/Linux OS Agent | Sign RPMs for AIX/Linux agents (GPG signing) |
Improvements
Issue ID | Module | Description |
|---|---|---|
| BVQ-19074 | Grafana: VMware | New dashboards for energy monitoring |
| BVQ-19110 | Alerting: Generic SAN | Better names for transmission rules |
| BVQ-19094 | Reporting | Strip out complexity from Generate Report Dialog |
| BVQ-19101 | K8s | Hide Warn Logs for container_cpu_cfs_throttled_seconds_total |
| BVQ-19079 | Brocade/Cisco: Adjust scanner config edit | Update remote information on user intention instead of automatically when accessing the page |
| BVQ-19179 | BVQ Server | Log update info to bvq-server.log |
| BVQ-19097 | BVQ Server | Disable weak SSL/TLS exchange methods/ciphers |
| BVQ-18491 | BVQ Maintenance Mode | Spelling changes - Maintenance Wizard |
| BVQ-19108 | Java | migration to version 17 (LTS) |
Bug fixes
| Severity | Issue ID | Module | Description |
|---|---|---|---|
| Critical | BVQ-19184 | Brocade: Topo persist | DuplicateKeyExceptions for brocade_rule |
| Critical | BVQ-19149 | Scanner: Brocade | Switches with different password are discovered but not scanned |
| Major | BVQ-19148 | Reporting | Custom Reports fail due to method violation |
| Major | BVQ-19069 | Grafana | Tables don't react to selected objects if reachable by is based on generic OTs |
| Major | BVQ-19122 | PowerVM | Incomplete performance data after move to HMC group |
| Major | BVQ-19164 | Alerting: Exclude | Re-include "At next Alert rule run after" doesn't allow change of date |
| Major | BVQ-18885 | Alerting | Division expression not accepted in condition |
| Minor | BVQ-19103 | Alerting | Invalid Rules aren't reflected as invalid in the UI |
| Minor | BVQ-19104 | SVC | Empty perf_enclosure T1 und T2 collections |
| Minor | BVQ-18804 | VMware | NVMe Host Storage Adapter not detected correctly |
| Minor | BVQ-19119 | GUI: Favorites | Typo in Kubernetes analysis favo "Resource quotas" |
| Minor | BVQ-19159 | Scanner: PowerVM | Same HMCs in same scanner config do not lead to validation error |
| Minor | BVQ-19106 | Installer | Deinstall MiKTeX and Inkscape along with BVQ |
| Minor | BVQ-19137 | Scanner Status Notification | Fix cosmetic Bugs |
| Minor | BVQ-19118 | GUI: SVC: Events | NullPointerException when selecting an event |
| Minor | BVQ-19187 | Grafana | Non-generic OT in "Generic SAN - Switch Performance" dashboard |
| Minor | BVQ-19146 | Reporting | Scheduler offers HTML as default for reports |
| Minor | BVQ-19115 | Reporting | Save & Run works only after first save |
| Minor | BVQ-19175 | Reporting | Charts get misplaced if immediately preceded by level 4 header |
| Minor | BVQ-19133 | Reporting | Correctly handle invalid metrics in perf/capa charts and invalid columns in topo tables |
| Minor | BVQ-19139 | Reporting | Duplicate template name when importing templates |
, multiple selections available,