Scanner Connection failed
About this task
The task to add a scanner is failing
Applies to
All Versions and Systems
Procedure
- Make sure that you are able to connect to the specific system with the provided Credentials, IP.
- Make sure to use the correct system user, domain/local -administrator@vsphere.local
see also:
Prepare the systems that are to be monitored
BVQ uses data, collected by scanners from the connected systems.
The scanners are product-specific and managed in the BVQ°-Server in the scanner area.
Compute layer
Select +VMware and fill out the mandatory fields
Do not forget to append "/sdk" to the URL
Username has to be "user@vcenter"
Do not forget to check the event scan if you like to see VMware event data in BVQ.
Do not change the defaults unless there is an important reason to do so.
You cannot access the SDK URL at https://servername/sdk
The service at https://localhost/sdk is not an HTML webserver that can serve web pages.
After setting up the VMware scanner, use the save button, to finish your work.
The Storage Adapter Performance Scan scans all paths from each SCSI disk to SAN and will generate a lot of data.
Switch this on, only when you need this data.
This can also be switched for only some hours when you see the need to analyze round robin behavior of storage paths.
Select +PowerVM and fill out the mandatory fields
After setting up the scanner, use the save button, to finish your work
Select +AIX or +Linux and fill out the mandatory fields
Press Save&Exit to complete the scanner configuration
Note: Unlike other BVQ scanners, the AIX and Linux scanners are not actively scanning any systems but are waiting for them to send data. This means, a BVQ Agent for AIX or Linux needs to be installed on every partition that should be monitored by BVQ before any data is available for analysis
Network layer
Brocade REST interface is only available for Fabric O8.2.1 and higher. Visit Network layer for more information.
Select +Brocade and fill out the mandatory fields
Do not change the defaults unless there is an important reason to do so.
Select a Switch (or Director) in your SAN that has the highest firmware level and has the most performant hardware (Core directors preferred)
and insert its address in the corresponding fieldsInsert the user credentials you prepared in Step 1
Click "Update switches" below "Discovered switches" → this will take a while, please be patient
BVQ will discover the IP addresses of all connected Switches and will ask every discovered Switch for additional connected Switches until no more Switches are found.
All discovered Switches are Part of a (virtual) Fabric and all discovered Fabrics are part of a SAN, that is scanned completely by this BVQ Scanner instance.It is essential, that the principal switch of each fabric can be found in that discovery to identify all the Fabrics inside that SAN.
Please review the list of discovered Switches for completeness
It is recommended to have the same user credentials on all Switches. If that is not possible, you can change the user credentials of each Switch found in the first discovery. Please hit "Update Switches" again after that, if the list of Switches is not complete as expected.
After setting up this Scanner hit the "Save configuration" button to finish your work.
Select +CISCO and fill out the mandatory fields
After setting up the scanner, use the save button, to finish your work
Storage layer
Select +SVC and fill out the mandatory fields
After setting up the scanner, use the save button, to finish your work
Select +Netapp and fill out the mandatory fields
After setting up the scanner, use the save button, to finish your work
Select +EmcUnity and fill out the mandatory fields
After setting up the scanner, use the save button, to finish your work.
Abstract
The BVQ Offline scanner - for Storage, Compute or Network - is the application of choice to collect information for a BVQ analysis without installing any program. Start this application on any Windows, Linux or MacOS based server or laptop and let it collect configuration and performance information for a dedicated timeframe (hours up to days or weeks). This information is put into a single zip file which can be sent to a central BVQ service point (SVA or partners) where it will be analyzed for you. Transmission of the offline scanner zip file is encrypted by a https connection when sending it via SVA Sharefile.
The zip file packaged by the offline scanner consists of
- topology information (configuration and runtime parameters)
- performance statistics
- event- and audit-logs (if applicable)
Security
Topology and performance files include metadata of objects, like name, size and attributes plus performance statistics.
Data residing on an object will NOT be collected!
There is one version of the tool available for each platform. To see which data is collected and how the data is collected, click on the desired platform:
- Storage:
- Network:
- /wiki/spaces/~557058f85a2b71be2d496e8e4575a825a92089/pages/13831307
- Brocade (BNA)
- Cisco
- Compute:
Some thoughts before you use the offline scanner
- Running the BVQ Offline scanner is easy and non-critical. No installation is needed and it can be run on any MS Windows, Linux or MacOS based client system with TCP/IP connection to the systems to scan.
- Scan time is dependent on the objective of the scan:
- 10 -14 days of scanning is sufficient to prepare for any kind of analysis like risk analysis or IO density analysis for storage planning. This timeframe is also used for a BVQ PoC.
- 5-7 days of scanning is the minimum to prepare for a risk analysis.
- 1-2 days of scanning can be used for short term performance issue analysis (e.g. peak latency analysis) given that the bottleneck actually happens in this time. (Please let us know, when exactly the performance issue occurred.)
- There's a video tutorial available which shows how to use the scanner for SVC/Storwize:
Video how to run the BVQ Offline scanner - Contact your BVQ partner or the BVQ team to prepare an analysis of the data:
https://www.bvq-software.de/en/contact/ or send a mail to BVQ@sva.de
Step 1: Download & Unpack the Offline scanner
Download the Offline scanner on a Microsoft Windows or Linux system that has access to the system(s) which need to be scanned:
Note: The download opens a zip file browser! Please use the blue download button on the right top of the page to download the zip file:
Unzip the Offline scanner to an existing or new folder.
Step 2: Prepare the Systems to be scanned
On IBM SVC/Storwize systems:
Step 3: Data Collection
You need to go through a sequence of dialogs to get the offline scanner started:
- Configure access to the system
- Run Pre-requisite checks
- Scan the system
- Zip and store the collected data
The scanner will run until you force it to stop. Until then, the scanner will continuously gather performance statistics and configuration information.
After the scan has finished you need to upload the resulting data zip file to the BVQ service point to be analyzed there.
Step 3.1: Start the scanner
Start the scanner by double clicking on the appropriate executable: bvq-<product>-scanner-offline.exe
.
Step 3.2: Define a profile
Offline scanner profiles allow to run more than one scanner in parallel. This is helpful in case multiple systems need to be scanned at the same time, e.g. two SVC systems in an remote copy partnership.
If you want to scan multiple systems at the same time:
Start one scanner per system. You get a separate control window for each instance.
Configure one profile (IP connection information and user credentials) for each system as described below. Each profile configuration is kept and can be reused.
Each profile uses its own working directory in the path underneath the installation directory
./instances/<profilename>
After finishing one instance the scanner offers to store the result ZIP archive file in the working directory with ann individual filename.
Step 3.3 Configure system access
Fill in the information that is required to access the system which needs to be scanned:
V7000 Unified
If you scan a V7000 unified then please enter the IP address of the storage system, not the unified heads! The offline scanner can not distinguish between these systems and will not collect any data if the wrong IP address is entered.
Note: Don't forget to adjust the "Max age of data in days"!
Step 3.4: Start the automated prerequisite check
Once the access is configured, the offline scanner will run some pre-requisite checks to make sure the system to be scanned is accessible and there is sufficient free space in the filesystem to store the collected data.
The tool cannot continue until all checks are successful!
Step 3.5: Scanning
In the next step, the offline scanner starts to collect data and copies the topology, eventlog and performance statistics in the according instance-directories.
Example: SVC Offline scanner
Note: If the tool is running for a longer timeframe, please check from time to time that the scanner is still running fine and still able to access the scanned system. The easiest way to do this, is to open the directory ./instances/<profilename>
and check whether new data is coming in.
If scan time is over or you decided to stop the scanner earlier, click Finish to end the scan process.
Step 3.6: Stop scanning and store the results
Finally the tool packs all gathered information in a ZIP archive file. The tool defaults to store this to the instance working directory.
Example: SVC offline scanner
Step 4: Contact us to upload the data for analysis or reporting
Contact us to prepare the upload for you
https://www.bvq-software.de/en/contact/ or send a mail to BVQ@sva.de
Please use the following request and enter 'offline scan' into the message field.
Your BVQ team can now start the analysis of the data and provide feedback on the results!